When engineering complex electrical systems, the reliability of internal wiring directly impacts overall operational stability. The UL2570 PVC Sheath Braided Copper Wire is purposefully constructed to meet these demanding requirements across global industrial markets. Featuring a specially formulated UV-resistant PVC jacket, the exterior feels smooth and highly flexible to the touch, yet it provides an exceptionally tough barrier against prolonged sunlight exposure and harsh environmental degradation. Inside, the high-purity tinned or bare copper conductors ensure long-lasting, stable conductivity while resisting oxidation over time. Fully compliant with UL758 and UL1581 international standards, this wire is engineered to bridge the gap between rigorous safety compliance and practical durability. Whether deployed in outdoor installations, heavy automation machinery, or enclosed industrial equipment, the precise construction prevents electrical breakdown, ensuring that power and sensitive signals flow without interruption.
Rated Voltage: 600V or 1000V. This robust rating supports stable power transmission in demanding industrial environments, effectively preventing electrical breakdown during peak operational loads.
Rated Temperature: 80ºC. The insulation maintains its structural integrity and flexibility without softening, melting, or degrading in elevated thermal conditions.
Insulation Material: PVC. Engineered for optimal dielectric strength, it provides consistent electrical isolation between internal cores.
Jacket Material: PVC. The specialized outer sheath acts as a tough, weather-defending barrier that resists cracking under direct ultraviolet exposure and physical abrasion.
Conductor: Tinned or Bare, Stranded or Solid Copper. Delivers exceptional conductivity coupled with superior oxidation resistance, tailored to remain pliable for complex routing.
Optional: AL-Mylar, Copper Braided. This dual-shielding configuration effectively blocks Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI), securing signal clarity in noisy environments.
Reference Standard: UL758, UL1581, C22.2 No.210. Fully compliant with rigorous global safety and performance benchmarks for immediate market integration.
Passes UL VW-1 & CSA FT1 vertical flame test. Ensures superior fire retardancy, meaning the material will self-extinguish to significantly reduce fire propagation risks in enclosed spaces.
Uniform insulation thickness of wire to ensure easy stripping and cutting. The perfectly centered conductor minimizes processing time, allowing automated wire-stripping machines to operate smoothly without damaging the inner core.
For internal wiring of electronic and electrical equipment and appliance, motor, automation machine, machine tool equipment, logistics transportation equipment, cranes, automatic elevators, lifting parking, measurement, detection and control, air conditioning systems, refrigeration equipment, office automation equipment and data processing systems, driving, etc. Highly adaptable for both dynamic and static high-frequency routing.
Understanding the exact physical and electrical characteristics of your wiring components is critical for accurate project planning. The following technical data sheet outlines the precise dimensional and resistance values for the UL2570 series. Each configuration, ranging from 2-core to 5-core setups across various AWG sizes, is manufactured with incredibly low eccentricity. By maintaining uniform thickness across the entire spool, assembly lines can operate at peak efficiency. Review the parameters below to match the specific voltage and resistance requirements of your automation machinery or HVAC systems.
Conductor | Insulation | Jacket | Max. Cond. Resistance at 20°C | |||||
No. of Cores | AWG | Construction | Diameter | Thickness | Diameter | Thickness | Diameter | |
2 | 26 | 7/0.16 | 0.48 | 0.76 | 2.1 | 0.76 | 5.9 | 150 |
24 | 11/0.16 | 0.61 | 2.2 | 6.1 | 94.2 | |||
22 | 17/0.16 | 0.76 | 2.4 | 6.5 | 59.4 | |||
20 | 26/0.16 | 0.94 | 2.6 | 6.9 | 36.7 | |||
3 | 26 | 7/0.16 | 0.48 | 2.1 | 6.2 | 150 | ||
24 | 11/0.16 | 0.61 | 2.2 | 6.4 | 94.2 | |||
22 | 17/0.16 | 0.76 | 2.4 | 6.8 | 59.4 | |||
20 | 26/0.16 | 0.94 | 2.6 | 7.3 | 36.7 | |||
4 | 28 | 7/0.127 | 0.38 | 2 | 6.6 | 239 | ||
26 | 7/0.16 | 0.48 | 2.1 | 6.7 | 150 | |||
5 | 28 | 7/0.127 | 0.38 | 2 | 7.2 | 239 | ||
26 | 7/0.16 | 0.48 | 2.1 | 7.5 | 150 | |||
※The above datasheet is for reference only, please refer to the final specification. | ||||||||
Industrial projects rarely fit into a standardized mold, which is why flexible manufacturing capabilities are essential for large-scale procurement. The UL2570 braided copper wire supports comprehensive OEM customization to perfectly align with specific engineering demands. Depending on the complexity of the routing environment, procurement teams can specify exact wire gauges (AWG), core counts, and distinctive jacket colors for easier phase identification during complex installations. For environments plagued by heavy electromagnetic interference (EMI) or radio frequency interference (RFI), optional AL-Mylar and copper braided double-shielding structures can be integrated to safeguard sensitive data transmission.
Beyond physical customization, every spool undergoes a rigorous testing protocol before leaving the facility. To guarantee absolute reliability in extreme conditions, the cables are subjected to intensive spark testing, dielectric withstand voltage assessments, and accelerated aging evaluations. The successful passing of the UL VW-1 and CSA FT1 vertical flame tests further confirms that the materials will self-extinguish, drastically reducing fire propagation risks. This uncompromising approach to quality control ensures consistent performance, batch after batch, securing the operational integrity of your most critical electrical equipment.
Since our establishment in 2013, XSD Cable has been one of the professional manufacturer in the field of wire and cable.