UL1007 PVC Insulated Flat Ribbon Cable
① Rated temperature: 80ºC
② Rated voltage: 300V
③ Reference Standard: UL758, UL1581, C22.2 No.210
④ Passes UL VW-1 & CSA FT1 vertical flame test.
⑤ Uniform insulation thickness of wire to ensure easy stripping and cutting.
⑥ For internal wiring of electronic and electrical equipment and appliance.
Conductor | Insulation | Max. Cond Resistance at 20°C (Ω/km) | |||
AWG | Construction (No./mm) | Diameter (mm) | Thickness (mm) | Diameter (mm) | |
30 | 7/0.10 | 0.30 | 0.41 | 1.12 | 381 |
28 | 7/0.127 | 0.38 | 0.41 | 1.20 | 239 |
26 | 7/0.16 | 0.48 | 0.41 | 1.30 | 150 |
24 | 11/0.16 | 0.61 | 0.41 | 1.43 | 94.2 |
22 | 17/0.16 | 0.76 | 0.41 | 1.58 | 59.4 |
20 | 26/0.16 | 0.94 | 0.41 | 1.76 | 36.7 |
18 | 41/0.16 | 1.18 | 0.41 | 2.00 | 23.2 |
16 | 26/0.254 | 1.49 | 0.41 | 2.32 | 14.6 |
FAQ
Q1: Are you a manufacturer?
A1: Yes, we are a manufacturer located in Dongguan city of China. We are able to provide OEM/ODM services for wires, cables, custom cable assembly around the world.
Q2: Can I get a free sample?
A2: Yes, we are willing to provide sample in stock for free but freight collected. Welcome to contact us for customized products.
Q3: Can you assure the quality of your products?
A3: Absolutely! Our workshop is equipped with state-of-the-art machinery and advanced testing equipment. We adhere strictly to international standards and customer specifications throughout our production process and quality control procedures. Rest assured, our commitment is to deliver products of the highest quality.
Q4: How long does it take for the products to be delivered?
A4: Typically, the delivery lead time for wire production is approximately 10-15 days, while cable assembly may take around 20-40 days. The exact timeframe depends on factors such as the quantity ordered and the complexity of the products.
UL1007 PVC Insulated Flat Ribbon Cable
① Rated temperature: 80ºC
② Rated voltage: 300V
③ Reference Standard: UL758, UL1581, C22.2 No.210
④ Passes UL VW-1 & CSA FT1 vertical flame test.
⑤ Uniform insulation thickness of wire to ensure easy stripping and cutting.
⑥ For internal wiring of electronic and electrical equipment and appliance.
Conductor | Insulation | Max. Cond Resistance at 20°C (Ω/km) | |||
AWG | Construction (No./mm) | Diameter (mm) | Thickness (mm) | Diameter (mm) | |
30 | 7/0.10 | 0.30 | 0.41 | 1.12 | 381 |
28 | 7/0.127 | 0.38 | 0.41 | 1.20 | 239 |
26 | 7/0.16 | 0.48 | 0.41 | 1.30 | 150 |
24 | 11/0.16 | 0.61 | 0.41 | 1.43 | 94.2 |
22 | 17/0.16 | 0.76 | 0.41 | 1.58 | 59.4 |
20 | 26/0.16 | 0.94 | 0.41 | 1.76 | 36.7 |
18 | 41/0.16 | 1.18 | 0.41 | 2.00 | 23.2 |
16 | 26/0.254 | 1.49 | 0.41 | 2.32 | 14.6 |
FAQ
Q1: Are you a manufacturer?
A1: Yes, we are a manufacturer located in Dongguan city of China. We are able to provide OEM/ODM services for wires, cables, custom cable assembly around the world.
Q2: Can I get a free sample?
A2: Yes, we are willing to provide sample in stock for free but freight collected. Welcome to contact us for customized products.
Q3: Can you assure the quality of your products?
A3: Absolutely! Our workshop is equipped with state-of-the-art machinery and advanced testing equipment. We adhere strictly to international standards and customer specifications throughout our production process and quality control procedures. Rest assured, our commitment is to deliver products of the highest quality.
Q4: How long does it take for the products to be delivered?
A4: Typically, the delivery lead time for wire production is approximately 10-15 days, while cable assembly may take around 20-40 days. The exact timeframe depends on factors such as the quantity ordered and the complexity of the products.