UL AWM 11627 105℃ 2000V Copper Conductor Power Cable Control Cable
Rated Voltage: 2000V
Rated Temperature: 105ºC
Insulation Material: PVC
Conductor: Tinned or Bare, Stranded or Solid Copper
Reference Standard: UL758, UL1581, C22.2 No.210
Passes UL VW-1 & CSA FT1 vertical flame test.
Uniform insulation thickness of wire to ensure easy stripping and cutting.
For internal wiring of electronic and electrical equipment and appliance, EV Charger, Power Modules, PV Inverter, Solar System Wiring, etc.
Conductor | Insulation | Max. Cond. Resistance at 20°C (Ω/kft) | |||
AWG | Construction (No./mm) | Diameter (mm) | Nom. Thickness (mm) | Diameter (mm) | |
26 | 7/0.16 | 0.48 | 0.76 | 2.00 | 150.00 |
24 | 11/0.16 | 0.61 | 0.76 | 2.13 | 93.25 |
22 | 17/0.16 | 0.76 | 0.76 | 2.28 | 55.00 |
20 | 26/0.16 | 0.94 | 0.76 | 2.46 | 34.60 |
18 | 41/0.16 | 1.18 | 0.76 | 2.70 | 21.80 |
16 | 26/0.254 | 1.50 | 0.76 | 3.02 | 14.64 |
14 | 41/0.254 | 1.90 | 0.76 | 3.42 | 9.25 |
12 | 65/0.254 | 2.40 | 0.76 | 3.92 | 5.82 |
10 | 105/0.254 | 3.00 | 0.76 | 4.52 | 3.66 |
8 | 165/0.254 | 3.77 | 1.14 | 6.05 | 2.35 |
6 | 7×38/0.127 | 5.41 | 1.14 | 7.69 | 1.48 |
4 | 7×60/0.127 | 6.81 | 1.52 | 9.85 | 0.928 |
2 | 19/138/0.127 | 8.62 | 1.52 | 12.00 | 0.59 |
※The above datasheet is for reference only, please refer to the final specification. |
Q1: Are you a manufacturer?
A1: Yes, we are a manufacturer located in Dongguan, Guangdong, China. We can provide OEM/ODM service for customers around the world.
Q2: Can I get a free sample?
A2: Yes, we can provide the existing items' samples without charge but freight collected. If there is any special samples requirement, please contact us for more details.
UL AWM 11627 105℃ 2000V Copper Conductor Power Cable Control Cable
Rated Voltage: 2000V
Rated Temperature: 105ºC
Insulation Material: PVC
Conductor: Tinned or Bare, Stranded or Solid Copper
Reference Standard: UL758, UL1581, C22.2 No.210
Passes UL VW-1 & CSA FT1 vertical flame test.
Uniform insulation thickness of wire to ensure easy stripping and cutting.
For internal wiring of electronic and electrical equipment and appliance, EV Charger, Power Modules, PV Inverter, Solar System Wiring, etc.
Conductor | Insulation | Max. Cond. Resistance at 20°C (Ω/kft) | |||
AWG | Construction (No./mm) | Diameter (mm) | Nom. Thickness (mm) | Diameter (mm) | |
26 | 7/0.16 | 0.48 | 0.76 | 2.00 | 150.00 |
24 | 11/0.16 | 0.61 | 0.76 | 2.13 | 93.25 |
22 | 17/0.16 | 0.76 | 0.76 | 2.28 | 55.00 |
20 | 26/0.16 | 0.94 | 0.76 | 2.46 | 34.60 |
18 | 41/0.16 | 1.18 | 0.76 | 2.70 | 21.80 |
16 | 26/0.254 | 1.50 | 0.76 | 3.02 | 14.64 |
14 | 41/0.254 | 1.90 | 0.76 | 3.42 | 9.25 |
12 | 65/0.254 | 2.40 | 0.76 | 3.92 | 5.82 |
10 | 105/0.254 | 3.00 | 0.76 | 4.52 | 3.66 |
8 | 165/0.254 | 3.77 | 1.14 | 6.05 | 2.35 |
6 | 7×38/0.127 | 5.41 | 1.14 | 7.69 | 1.48 |
4 | 7×60/0.127 | 6.81 | 1.52 | 9.85 | 0.928 |
2 | 19/138/0.127 | 8.62 | 1.52 | 12.00 | 0.59 |
※The above datasheet is for reference only, please refer to the final specification. |
Q1: Are you a manufacturer?
A1: Yes, we are a manufacturer located in Dongguan, Guangdong, China. We can provide OEM/ODM service for customers around the world.
Q2: Can I get a free sample?
A2: Yes, we can provide the existing items' samples without charge but freight collected. If there is any special samples requirement, please contact us for more details.